Alternating Relay for Pump Alternation with Selector Switch; Pump Hand-Off-Auto Switch with Pump Running Light; Full Alarm Circuit (Visual and Audible Alarms) Alarm Test and Silence Switch; Color Coded Internal Wiring; Connection Diagram and Schematic; 4 Float System (Off, On, Lag and High Water) Built and Labeled to UL 508A Standard; Spec Sheet
Details2 HP Dual Seal Grinder Pump & HF2OU30F2 30' Float Switch Start & Run Capacitors in the Control Panel. The vortex impeller design of the grinder pump provides non-overloading performance and prevents clogging. This grinder pump produces capacities up to 42 gpm with heads up to 133 feet. Some of the grinder pump features: Single Phase
DetailsPump Switches are used to directly control the operation of a pump. They are normally wide-angle switches which means they operate over a range of approximately 70o to 90o. Pump switches are available with piggyback plugs and with bare leads. Some can also be used with control panels. To learn more about the features and benefitsRead more
DetailsTo order Myers Pump Repair Parts - Call PumpProducts at 800-429-0800. About PumpProducts: PumpProducts is the leading Myers Pump Parts Distributor. We stock a full line of Myers Pump Replacement Parts for all of the Myers manufactured pumps. Overnight delivery of Myers Pump Parts is made possible by Myers Pump Products Express ...
DetailsThe intrinsically-safe panel, in conjunction with an explosion-proof pump, will provide a system that will not allow ignition of the explosive gases. The purpose of the control panel is to cycle a pump automatically. Each panel comes standard with pump run light (s), a high water audible and visual alarm, seal fail indicator (s), and a UL listing.
DetailsPump Hand-Off-Auto Switch with Pump Running Light; Alternating Relay for Pump Alternation with Selector Circuit; Full Alarm Circuit (Visual and Audible Alarms) Alarm Test and Silence Switch; Color Coded Internal Wiring; Connection Diagram and Schematic; 4 Float System (Off, On, Lag and High Water) Built and Labeled to UL 508A Standard; FLA ...
Details1 - 2HP Grinder Pump / 230 Volts - 1 Phase 1 - Alarm Panel with Float Switch for WD820 Systems or Simplex Control Panel with Auto Reversing for E840 Systems 1 - Junction Box 3 - Float Switches (E840 Systems only) 1 - Packaged Basin Assembly including: Poly Ribbed Basin with Blank Polyethylene Cover 1¼" Discharge Piping Square Guide Rail System
Details1 1/4" x 12" grinder pump single phase,1 or 2hp 1 1/4" grommet seal (field installed) check valve 1 1/4" npt progressing cavity 36" lifting bolt 16" x 1/4" steel 5/16" 304 stainless steel 1 1/4" pvc slip x slip pump plate pump power cord pipe seal switch cord piggyback float high water alarm (not included) check valve p/n 30-0223 1.25 ...
Details40/60 Pressure Switch for Well Pumps This pressure switch signals the pump to This pressure switch signals the pump to start when the water system drops to 40 psi (factory set) and stops at 60 psi (factory set). This switch is to be used with submersible well or jet pumps. It can be wired 115-Volt or 230-Volt.
DetailsPANEL . CONTROL FLOATS . SWITCH VARIATIONS NORMALLY OPEN (N/O) FLOAT SWITCH – CONTROL DUTY 2900 MERCURY SERIES – NARROW ANGLE FLOAT SWITCH GENERAL DESIGNED FOR ACCURATE LIQUID LEVEL CONTROL IN MANY APPLICATIONS INCLUDING ... Your grinder pump is furnished with a factory warranty against defects in …
DetailsEach float contains a heavy-duty mercury switch. The splice tube contains a holding relay which enables the floats to function in series. The holding relay eliminates pump chatter in turbulent conditions allowing the Double Float pump switch to operate relay control panels for larger pump applications. Controls pumps up to 1 HP at 120 VAC.
DetailsALTERNATOR SWITCH PUMP 1 ALT PUMP 2 ALTERNATOR SWITCH – STANDARD ON ALL DUPLEX PANELS, THIS SWITCH PROVIDES OPTIONS FOR‚ ALTERNATE PUMPS, USE ONLY PUMP 1 OR USE ONLY PUMP 2. IT IS USED WHEN A PUMP IS REMOVED FOR SERVICE. NOTE: The standard panels shown in this book are not designed to be used with …
Details4" 13 4" 3 4" GOLD CONTACTS MECHANICAL FLOAT SWITCHES INTRINSICALLY SAFE RATINGS: 160 µA TO 100 mA From 01 to 50 feet. Lengths are in even foot increments. OPTIONAL PEAR FLOAT Same MDI switch, larger pear shaped ˜oat This option only comes in ABS plastic HOW TO ORDER JWGF1OW1000 Mercury Float Switches 3 25 8" DIA. 9 16" 3" …
DetailsThe RK Series™ Single Phase Duplex panel is designed to control two 115/230 VAC single phase pumps in water and sewage installations. The protective inner door features panel operating status indicators, control buttons and provides access to the pump and control circuit breakers. The controller provides for alternation of the pumps for even usage. …
DetailsPump switches are designed to control the operation of a submersible pump. They can handle higher amperages than control switches. These are generally are wide angle which means they have to move 90 degrees to switch to the "ON" or "OFF" position. This is needed when controlling a pump because you have to be able to pump out a range of water and it also keeps the float …
DetailsNEX Series® Simplex Panel NEX Series® Duplex Panel. Single Phase Simplex Panels. Model 111 Model 115 Model 112. Single Phase Duplex Panels. Model 122. Three Phase Simplex Panels. Model 312. Three Phase Duplex Panels. Model 322 Model 32S Model 32XR. Capacitor Start Run. Model 113 Model 123. Intrinsically Safe Panels. Model 114 Model 124 Model ...
DetailsP/N 10-1212 Simplex panel, Model E815 pump, NEMA 4X, with high water alarm and pump circuit breaker, less fl oat switches. (C) FLOAT SWITCHES - 2 required Pump: One pump switch Alarm: One control switch P/N 10-0706 piggy-back pump switch with 20' cord P/N 10-0311 piggy-back pump switch with 25' cord P/N 10-1956 piggy-back pump switch with 35' cord
DetailsAre you looking for a reliable grinder pump system? Building a new home, or replacing an outdated sewer grinder station? Made in the USA, we offer top of the line, highly reliable & heavy duty grinder pumps & systems that are in stock and available to ship today! Grinder pumps are often used in new developments or where septic tanks are being replaced that can not gravity …
Detailspreset level, the grinder pump automatically turns on, grinds the waste, and pumps it out of the tank via a pressure discharge line into the public sewer system. A grinder pump is a pumping system with many components - tank, pump assembly, level controls, piping and valves, and electrical. A grinder pump will normally run for one
DetailsSPI Part #20A113, Model 20HMDNOP, Pump Down Heavy-Duty Mechanical Float Switch $ 62.46; SPI Part #20A706, Model 15CRDSW, Pump Down M-Pilot Series Mercury Control Duty Switch with external weight $ 35.06; SPI Part #20A703, Model 10CRUPC, Pump Up M-Pilot Series Mercury Control Duty Switch $ 27.35
Details(by pump mfg.) submersible grinder pump (2hp min.dual-seal) (see specifications) 36" min. dia. reinforced fibreglass basin, must meet astm "d-3753" specification. mercury switch level control-mini roto float by anchor scientific w/internal weight wet well connections for 1.25", 2" & 4" pipe (see detail lp-20) (see note) 1.25" sch. 80 pvc piping ...
DetailsAFTER MARKET GRINDER PUMP E/One Upgrade If you're tired of constant service calls resulting from grease-fouled floats, jammed grinders, burned-out motors, and other grinder pump problems, it's time to call E/One. When you're having too many problems with your system's centrifugal grinder pumps, it can wear you down.
DetailsGrinder pump panel with mercury switch. Fiberglass basin assemblies include 1 2 HP grinder pump 1 alarm panel with float switch for WD820 systems or simplex control panel with autoreversing. Get Price. Email [email protected] We will strictly protect the privacy of users'personal information and never disclose it.
Details3/4 HP cast iron submersible sewage grinder pump with vertical float switch. Designed for a residential sewage application. Pumping vertical lift capacity of 35 feet. 2 step process that will grind standard sewage materials and propel them out of the pump. This pump is recommended for pumping raw sewage and for replacement of a sewage pump.
DetailsControl duty float switches are designed to be connected directly to a control panel to tell the control panel when to turn the pump on an off, or to signal the high level or low level alarm based upon the liquid level inside your tank. Both of our pump duty and control duty switches come in mechanical and mercury activated styles.
DetailsThe Junior M-Navigator Mercury Activated float switch is designed to control pump up to 1/2 HP at 120VAC or 1 HP at 240VAC. This float switch is normally open and is activated to "ON" in the raised position. It is not legal to use mercury float switches in the states of CT, RI, ME, CA, VT, IL, MN, NY, LA, NH, and MA.
DetailsAdd to Cart. Add to Product List. Zoeller 805-0001, Model M805, Shark Series, Grinder Pump With Vertical Float Switch, 3/4 Hp, 115 Volts, 1 Phase, 1-1/4" Npt Vertical Discharge, 40 Gpm Max, 45 Ft Max Head, 15 Ft Cord, Automatic. $0.00. Please Sign in to your account to see your pricing. which may be different from the price displayed. Add to Cart.
Details3. Determine the location on the control panel for the pump power cables and float switch cables. Drill holes to fit the type of cable fittings to be used. 4. Attach floats as shown in Typical Installation drawing and instruction manual. 5. Following step-by-step instructions and wiring diagram included with panel, complete connections of all ...
Details915-0007. Sewage Grinder System - Job Ready - 1/2 HP -115 volt with #10-1494 alarm. 18" x 30" fiberglass basin with 10' stack test steel cover. 2" vent - 1 1/4" discharge. $1,487.71. Due to size/weight and to ensure safe delivery, certain items ship by truck and have a $175 additional shipping fee per freight item.
DetailsThe diaphragm switch turns on when the water rises to a specific water level and the pump starts. The switch turns off when the water is drained out of the sump basin and the pump stops. These sump pump float switches and diaphragm switches connect directly to the pump, or the pump's power cord is plugged into the switch to control electric ...
Details